 Nuclear Event Detector
HSN-500
VB
8 9
Threshold Adjust
VH
14
VL
1
10 k
Detector (Pin Diode)
2
NED
Amplifier
Pulse Timer
BIT 6
LED
7
5
4
GND
C
RC
Logic Diagram
FEATURES:
* * * * * * * * * Detects ionizing radiation pulses Tested/certified detection threshold level Adjustable circumvention period 100% testable with built-in test Detection threshold adjustability Single +5V operation Designed-in radiation hardness Compliant to MIL-PRF-38534 Class H1 Flat pack (F) or DIP (L) packages
DESCRIPTION:
Maxwell Technologies' HSN-500 radiation-hardened Hybrid Nuclear Event Detector (NED) senses ionizing radiation pulses generated by a nuclear event, such as the detonation of a nuclear weapon, and rapidly switches its output from the normal high state to a low state with a propagation delay time of less than 20 ns. The active low Nuclear Event Detection signal (NED) is used to initiate a wide variety of circumvention functions, thus preventing upset and burnout of electronic components. The NED output is also used to initiate both hardware and software recovery. This high-speed, 14-pin hybrid detector is used in electronic systems as a general-purpose circumvention device to protect memory, stop data processing, and drive power supply switches as well as signal clamps. The HSN-500 is designed to operate through three critical environments: ionizing dose rate [1012 rad(Si)/s], gamma total dose [106 rad(Si)], and neutron fluence [5 x 1013 n/cm2]. In addition, the device is designed to function throughout the transient neutron pulse. The hybrid's discrete design ensures a controlled response in these radiation environments as well as immunity to latchup. The detection level and functionality of a sample of each HSN500 production lot are tested in an ionizing dose rate environment. A certificate is provided reporting the test results for the production lot. The detection threshold of the HSN-500 is adjustable within the range of 2 x 105 rad(Si)/s to 2 x 107 rad(Si)/s. This detection level can be preset by Maxwell or adjusted by the user. Less than a 30% variation in detection threshold can be expected over the entire operating temperature range.
Memory
RADIATION HARDNESS CHARACTERISTICS
* * * * * Dose Rate (operate-through): 1 x 1012 rad(Si)/sec Total Dose: 1 x 106 rad(Si) Neutron Fluence: 5 x 1013 n/cm2 Approximate Detection Range: 2 x 105 - 2 x 107 rad(Si)/sec Maxwell Technologies Specified, Controlled, and Tested
1.
Manufactured for Maxwell Technologies by Teledyne Micoelectronic Technologies to MIL-PRF-38534, Class H, no RHA
01.7.05 Rev 3
All data sheets are subject to change without notice
1
(858) 503-3300 - Fax: (858) 503-3301 - www.maxwell.com
(c)2005 Maxwell Technologies All rights reserved.
Nuclear Event Detector
TABLE 1. PIN DESCRIPTION
PIN NUMBER PIN FUNCTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Load Voltage, VL Nuclear Event Detector, NED No Connection External Capacitor External Capacitor Built In Test, BIT Package Ground and Case PIN Diode Bias, VB Threshold Adjust No Connection No Connection No Connection
HSN-500
Memory
No Connection Hardened Supply Voltage, VH
TABLE 2. ELECTRICAL CHARACTERISTICS
PARAMETER Hardened Supply Voltage Hardened Supply Current - Standby 1 - Operational 2 Load Voltage Load Current - Standby 1 - Operational 2 PIN Diode Bias Voltage - Standby 1 PIN Diode Bias Current - Standby Built-In-Test (BIT) 3,4
1
SYMBOL VH IH
-55 C
CONDITIONS < TA < 125 C
MIN 4.5
MAX 5.5 -30 120 20 100 2.25 20 100 5.5 25 0.5 10 --0.6 1.0 20
UNIT V mA
GROUP A SUBGROUP 1,2,3 1,2,3
VH = 5.5V ---
VL IL VL = 20V
----
V A mA V A V mA V A s V
1,2,3 1,2,3
VB IB VIH IIH VIL IIL tPW VOH VOL tD VIH = 4.0V VIL = 0.5V Pin 9 Open, VIH = 4.0V VL = 20V, IOH = -100 A IOL = 10 mA IOL = 100 mA
4.5 -4.0 ---10 18.5 ----
1,2,3 1,2,3 7,8 1,2,3 7,8 1,2,3 9,10,11 1,2,3 1,2,3
NED
Radiation Propagation Delay Time 5
ns
01.07.05 Rev 3
All data sheets are subject to change without notice
2
(c)2005 Maxwell Technologies All rights reserved.
Nuclear Event Detector
Table 2. Notes
HSN-500
1. Standby mode is the normal state of the device, defined as having the NED output (pin 2) in the "high" state. 2. Operational mode is in effect during the timeout period of the NED signal, characterized by having the NED output in the "low" state, causing the greatest current draw of the device. 3. BIT electrical characteristics are not guaranteed over the radiation range. 4. BIT may not meet specification when only a resistor is used to adjust the detection level. To use BIT in this situation, it is advised that a series resistor/capacitor combination is used. 5. Guaranteed but not tested over temperature. Time delay, tD, is measured at 50% points from the rising edge of the radiation pulse to the falling edge of the NED output at approximately 10 times the detection level.
0.100 TYP
0.600 0.015 0.003
0.145 MAX
TOP VIEW
0.070 0.002 0.500 MIN 0.795 0.600 0.100 TYP
Memory
14 13 12 11 10
9
8
0.495
1 2 3 4 5 6 7
14 13 12 11 10 1 2 3 4 5
9 6
8 7
0.300
0.495
0.145 MAX
0.795 0.010 0.002
0.200 0.016 DIA 0.020
Flatpack Hybrid Package HSN-500F
All tolerances are 0.005 unless specified
DIP Hybrid Package HSN-500L
MECHANICAL DIMENSIONS
Note: All dimensions in inches.
01.07.05 Rev 3
All data sheets are subject to change without notice
3
(c)2005 Maxwell Technologies All rights reserved.
Nuclear Event Detector
Important Notice:
HSN-500
The specifications presented within these data sheets represent the latest and most accurate information available to date. However, these specifications are subject to change without notice and Maxwell Technologies assumes no responsibility for the use of this information. Maxwell Technologies' products are not authorized for use as critical components in life support devices or systems without express written approval from Maxwell Technologies. Any claim against Maxwell Technologies must be made within 90 days from the date of shipment from Maxwell Technologies. Maxwell Technologies' liability shall be limited to replacement of defective parts.
Product Ordering Options
Model Number HSN-500 X Feature Option Details
Memory
Package
L = Dual In-line Package (DIP) F = Flat Pack
Base Product Nomenclature
Nuclear Event Detector
01.07.05 Rev 3
All data sheets are subject to change without notice
4
(c)2005 Maxwell Technologies All rights reserved.


▲Up To Search▲   

 
Price & Availability of HSN-500L

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X